Finding flaws with Forensic Analysis

A fertilizer plant in the Gulf of Mexico experienced a suction cavity high pressure ceiling leakage in one of their BB5 boiler feed pumps. By utilizing a forensic analysis, Hydro discovered a simple shortcut in the manufacturing process was costing thousands of dollars in repairs and great inconvenience.

Written by: Pete Erickson and  Todd Soignet
Published by: World Pumps

A BB5 barrel pump at a fertilizer plant along the Gulf of Mexico experienced reduced capacity due to suction cavity high pressure sealing leakage. This was not the first time their boiler feed pumps had experienced a loss of capacity. The pumps were only about a year and a half old and were part of a major expansion project at the plant.

Due to high lead times, the plant decided not to continue repairs, but instead do a simple swap out, when a Hydro service center was recommended by the client’s sister plant as a credible supplier who had the technical and engineering expertise needed to rebuild pumps to the highest quality standards.